Two numbers run almost every wall built in Australia: 450 and 600. If you have ever wondered why wall studs end up where they do in a drawing, those are the centres you will see repeated across residential plans, commercial fit outs and industrial sheds from Hobart to Darwin. There are variations and exceptions, but once you understand what sits behind the two default spacings, every other wall in the country starts to make sense.
This guide is organised the way a wall actually lives on site. Instead of starting with the standards and working out from there, it starts with the walls themselves and shows how spacing, stud size and gauge change depending on what each wall has to do. External load bearing walls follow one logic, internal load bearing walls follow another, non load bearing partitions follow a third, and specialty walls like fire rated or wet area walls follow their own rules on top of the basic numbers. By the end, you should be able to look at any wall in an Australian building and work out why the studs are where they are.
The one line summary. Australian wall studs sit at 450mm or 600mm centres in almost every case, with 450mm preferred for load bearing and brick veneer, and 600mm common for non load bearing and sheet clad walls. Timber follows AS 1684, steel follows the NASH Standard, and both are referenced by the National Construction Code.
Five inputs do all the work. If you know these five, you can work out any stud spacing in the country without opening a standard, then confirm it with the standard afterward.
The first input is load. A stud in a load bearing wall has to carry the weight of the roof, the floor above, or both, plus any live load from furniture, people and snow (in alpine areas). A stud in a non load bearing partition has to carry only itself and whatever is fixed to it. Those are very different jobs, and the spacing responds accordingly.
The second is wind zone. Wall studs resist wind pressure pushing into the external face of the building and suction pulling at it. Higher wind zones (N3 and above in non cyclonic areas, C1 and above in cyclonic areas) mean more force at every stud, which pushes spacing tighter or gauge heavier.
The third is the cladding or lining being carried. Brick veneer is a heavy wall tie load into the stud; sheet cladding is a lighter attachment load. Plasterboard on the inside is light; cement sheet or heavier lining is more. Every cladding has a maximum spacing for the ties, screws or brackets that attach it, and the studs behind it have to match that spacing.
The fourth is fire and acoustic performance. A fire rated or acoustically rated wall has specific stud and lining combinations that have been tested together, and you cannot change the stud spacing without potentially voiding the rating.
The fifth is the stud itself: its size, its material, and its gauge. A stud that is doing more work at the same spacing needs to be heavier, which in steel means a thicker gauge and in timber means a higher stress grade.
Four documents are worth knowing by name. You do not have to read them end to end, but every properly built wall in Australia traces back to one of these.
Standard | Applies To | What It Covers |
|---|---|---|
AS 1684 | Timber residential framing | Member sizes, spacings, bracing, tie downs and connectors for timber framed residential buildings |
NASH Standard Part 1 | Steel residential framing | Design criteria for cold formed steel framing in low rise residential and commercial buildings |
NASH Standard Part 2 | Steel residential framing | Non specific design solutions and span tables for steel studs, top plates, joists and trusses |
AS/NZS 4600 | Cold formed steel structures | Underlying structural design standard for the steel sections used in light gauge framing |
Both AS 1684 and the NASH Standard are called up by the National Construction Code, which is the regulation that governs what gets built. The Australian Steel Institute notes that the NASH Standard was the first and only industry standard specifically referenced in the NCC for steel framing in low rise buildings, which tells you how deeply embedded steel framing has become in Australian construction.
For a focused read on the design standard behind every steel section, our explainer on AS/NZS 4600 walks through what the standard covers and why it matters for the frame actually built on your job.
An external load bearing wall supports its share of the roof structure (and in a two storey building, the floor and walls of the storey above) while also resisting lateral wind load pushing on the outside of the building. This is the hardest working wall in a residential home, and its spacing reflects that.
Across most of Australia, external load bearing walls in single storey residential buildings and in the upper storey of two storey buildings sit at 450mm centres. In the lower storey of a two storey building, where the wall is carrying both the roof and the upper floor, 450mm centres is almost universal, and the gauge or timber size steps up to handle the extra load.
For single storey external load bearing walls in lower wind zones with a sheet clad finish rather than brick veneer, 600mm centres is permitted under the standards and used by some designers to reduce stud count. Whether it is appropriate depends on the wind zone, the specific cladding system and the structural calculation.
Brick veneer imposes a significant tie load on the wall studs behind it. Brick ties typically land at every stud or every second stud, and the stud has to be close enough together to keep tie spacing within the limits of AS 3700 Masonry Structures. For brick veneer, 450mm centres is generally expected, with the specific tie pattern set by the engineer based on wind zone and wall height.
For the trade off between brick veneer and alternative cladding methods for steel framed Melbourne homes, our guide on steel framing versus brick veneer covers how the cladding choice interacts with the framing specification.
An internal load bearing wall carries some combination of roof load, floor load, or the walls above, but is not exposed to wind. It still has to meet the strength and deflection criteria set in AS 1684 or the NASH Standard, but it does not need to resist outward wind pressure.
Internal load bearing walls in residential buildings typically use 450mm centres, matching the external load bearing walls of the same building for consistency. In some cases, particularly where the wall is only carrying a short run of ceiling or a light upper floor, 600mm centres is acceptable, and this is confirmed against the relevant span table. In commercial buildings, where the loads can be heavier and the ceilings higher, 450mm or even 300mm centres is more common.
Wall Position | Spacing | Timber Stud | Steel Stud |
|---|---|---|---|
Single storey internal | 450 or 600mm | 90 x 35mm MGP10 | 64 or 76mm C section |
Upper storey of two storey | 450mm | 90 x 35mm MGP10 | 76mm C section |
Lower storey of two storey | 450mm | 90 x 45mm MGP12 or F17 | 76 or 90mm C section, heavier gauge |
Commercial internal | 300 or 450mm | By engineer | 90 or 100mm C section |
A non load bearing partition is an internal wall that divides space but does not support any roof, floor or other wall load. Its job is to hold up its own linings, stay plumb and straight, and provide a surface for doors, cabinetry and services. These are the walls where the most spacing flexibility sits.
Residential non load bearing partitions in Australia almost always use 600mm centres. The wall only has to carry its lining (typically 10mm or 13mm plasterboard each side), any fixtures mounted to it, and its own weight. Commercial partitions often follow the same pattern, with 600mm centres for drywall partitions in office fit outs.
Non load bearing partitions tighten to 450mm centres or closer when heavy finishes are being fixed to them (full height tiling, large format mirrors, heavy joinery), when acoustic performance is critical, or when the lining itself needs tighter support (thinner linings or lower grade plasterboard can benefit from closer support).
Non load bearing residential partitions commonly use 70mm or 90mm wide steel studs at a lighter gauge than load bearing walls, or 70mm x 35mm timber in lighter applications. In commercial fit outs, 64mm, 76mm and 92mm steel stud widths are the common options, and the choice is driven more by cavity width (for services and insulation) than by structural need.
The steel stud frame service at CMC Steel Solutions covers the full range of residential and commercial stud profiles manufactured at our Craigieburn facility, and the steel wall frame service covers complete wall assemblies rather than studs alone.
Facade frames are a specialty subset of external wall framing, often used for cladding systems on commercial, residential or student accommodation buildings where the facade is a separate layer from the main structure. The framing behind the facade carries the weight and wind load of the cladding and transfers it back to the primary structure.
Spacing on facade frames is driven by the facade system itself: the maximum span of the cladding panels, the attachment grid of the facade subframe, and the wind load at the height of the facade. Facade frames commonly use 600mm centres but are frequently specified tighter where the facade is heavy or the attachment grid demands it. These are typically engineered rather than pulled from standard span tables.
Our facade steel frame service covers the specific design and manufacture of light gauge facade frames, including the kind of student accommodation and mid rise residential facade projects we handle across Melbourne.
Fire rated walls have to maintain their structural adequacy, integrity and insulation for a prescribed time during a fire. The specification is tested as a complete system, meaning the stud, the lining, the joint treatment and the fixing pattern all contribute to the rating. You cannot change one element without potentially compromising the rating.
A fire rated wall at FRL 60/60/60 (structural adequacy 60 minutes, integrity 60 minutes, insulation 60 minutes) will have a tested stud spacing specified by the manufacturer of the tested system. In most residential and light commercial systems, that spacing is 600mm centres with specific stud profiles and gauges. For higher ratings (90/90/90, 120/120/120) the tested systems commonly tighten to 450mm centres or specify heavier gauges.
Steel studs are non combustible under AS 1530.1, which gives steel framing a head start on fire rated walls. Timber framing can achieve equivalent FRLs with correctly specified lining systems, but the test paths are different, and substituting one material for another in a fire rated specification is not something to do informally.
The technical detail on how steel framing handles fire is covered in our guide to the fire resistance of structural steel framing, which explains what non combustible actually means for a framing specification.
Bathroom, laundry and kitchen walls have to tolerate moisture, which matters for both the stud material and the lining system. Spacing itself does not change in wet areas (450 or 600mm as per the structural job), but the detailing around spacing does.
Steel studs are naturally advantaged in wet areas: they do not swell, warp or absorb moisture, so the tile substrate stays flat over time. Where heavy point loads exist (a wall mounted vanity, a shower niche, a tiled hob), the studs are typically supplemented with extra noggins or doubled studs at the fixture location, regardless of the base spacing. In coastal Victorian suburbs, the corrosion category applied to the stud becomes important too.
The corrosion and coating considerations for steel framing near the Victorian coast are covered in our guide to corrosion resistance and coastal steel framing, which is relevant wherever humidity or salt spray is a factor.
Spacing in higher wind zones tightens, gauge increases, or both. Below is an indicative snapshot of how a typical single storey external load bearing wall in a residential home moves across wind zones. The exact specification is always confirmed against the span table and the engineer.
Wind Zone | Typical Spacing | Typical Steel Gauge (BMT) | Notes |
|---|---|---|---|
N1 | 600mm | 0.75mm | Lightest residential loading |
N2 | 600 or 450mm | 0.75 or 1.0mm | Suburban Melbourne default |
N3 | 450mm | 1.0mm | Coastal fringe, elevated sites |
N4 | 450mm | 1.15mm | Exposed coastal, high wind |
C1 and above | 450 or 300mm | 1.6mm or heavier | Cyclonic zones, specific engineering |
In cyclonic areas (C1 to C4), the whole frame specification tightens: studs, top plates, tie downs, bracing and connectors all respond to the higher wind pressures and uplift forces. The NASH Standard Part 2 Cyclonic provides the specific span tables for these zones.
Spacing is only half of a wall specification. The other half is the stud itself, which has three primary dimensions worth understanding.
Stud depth is the dimension that sets the cavity width of the wall. In Australia, 90mm is the standard timber stud depth for residential external and load bearing walls, with 70mm used for lighter internal walls. In steel, the common stud depths are 64mm, 76mm (also quoted as 75mm), 90mm (also quoted as 92mm) and 100mm, with 76mm and 92mm the two residential standards.
In timber, stud width is the 35mm or 45mm dimension, which determines how much fixing surface the stud offers for lining and cladding. In steel, the flange width is the horizontal part of the C section, which typically runs from 35mm to 50mm depending on the profile.
Gauge is the thickness of the steel sheet itself, before coating. Residential light gauge steel studs typically run from 0.55mm BMT (lightest non load bearing) to 1.6mm BMT (heavier load bearing or higher wind zone). The relationship is simple: for a given spacing and span, a thicker gauge can carry more load, and for a given load, going thicker lets you move to a wider spacing or a shallower stud depth.
Wall Type | Spacing | Stud Size and Gauge | Common Application |
|---|---|---|---|
Internal non load bearing | 600mm | 64mm C section, 0.55 to 0.75mm BMT | Residential and commercial partitions |
Residential external, single storey | 450 or 600mm | 76mm C section, 0.75 or 1.0mm BMT | Suburban family home |
Residential external, lower storey | 450mm | 92mm C section, 1.0 or 1.15mm BMT | Two storey ground floor walls |
Load bearing commercial | 450 or 300mm | 90 or 100mm C section, 1.15 to 1.6mm BMT | Office and multi residential |
When choosing a steel stud supplier, gauge and coating are the two specifications where corners get cut in the market. Our guide on how contractors and distributors choose a reliable steel stud supplier covers what to look for in a supplier beyond price.
Wall stud spacing does not sit in isolation. The studs have to pick up loads from the roof or floor above and transfer them to the floor or footing below. Where the spacing of each layer does not align, the top and bottom plates have to spread the load, which puts a lower limit on plate section.
The floor side of the equation is covered in detail in our guide to floor joist spacing in Australian builds, which explains the 300, 450 and 600mm pattern for joists and how it dovetails with stud spacing above.
Roof trusses are the other end of the chain. Most residential trusses sit at 600mm or 900mm centres, which almost never aligns one to one with stud spacing of 450mm. The top plate becomes the load spreader between the two systems, and its dimensions respond to that job.
A steel stud at 450mm centres is doing the same spacing job as a timber stud at 450mm centres, but the two members themselves are very different. Here is how the comparison plays out in practice.
Property | Timber Stud | Steel Stud |
|---|---|---|
Governing standard | AS 1684 | NASH Standard Parts 1 and 2 |
Dimensional stability | Shrinks and swells; straight stud becomes bowed | Dimensionally stable for life |
Termite resistance | Requires treatment | Not required |
Combustibility | Combustible | Non combustible (AS 1530.1) |
Straightness tolerance | Varies with grade and seasoning | Manufactured to tight tolerances |
Weight | Heavier per linear metre | Lighter per linear metre |
Warranty | Supplier dependent | Up to 50 years on TRUECORE |
Service penetrations | Field drilled, limited by rules | Factory pre punched where available |
For the specific practical details of how timber and steel framing meet on the same build (because almost no real building is one material alone), see our guide on wood and steel hybrid framing, which covers the junctions, fastener choices and corrosion considerations when the two materials touch.
Dropping from 600mm to 450mm centres adds roughly 33 per cent more studs to the wall. That is real money, and it should not be spent on a whim. Three scenarios make the tighter spacing worth it.
The first is where a tested system (fire or acoustic) requires it. There is no choice to be made in that case; the rating is the design parameter.
The second is where the wall is carrying an unusually heavy load or a concentrated point load that needs to be shared across more studs. A wall supporting an engineered beam above, for example, or a run of wall with multiple heavy wall mounted fixtures.
The third is where the cladding or lining system cannot span 600mm comfortably. Brick veneer with tight tie spacing, heavy cement sheet cladding, or thin lining systems that benefit from tighter support.
Outside those three cases, the extra studs are often an unnecessary cost. The full cost picture for an Australian steel frame build puts the choice in context against the whole project budget.
Residential wall studs in Australia sit at 450mm or 600mm centres in almost every case. 450mm is the default for load bearing walls, brick veneer and most two storey upper floor walls. 600mm is common for single storey external walls in lower wind zones with sheet cladding, and for internal non load bearing partitions. The spacing is specified in AS 1684 for timber and the NASH Standard for steel.
There is no single standard spacing because it depends on what the wall is doing. For residential external load bearing walls, 450mm centres is the most common default. For non load bearing internal partitions, 600mm centres is standard. For heavily loaded commercial walls or higher wind zones, 300 or 450mm centres is used.
Residential wall studs in Australia are typically 90mm deep (the dimension across the wall, setting the cavity width) in both timber and steel. In timber, the stud is usually 35mm or 45mm wide. In steel, the gauge of the stud (the thickness of the steel sheet itself) runs from about 0.55mm BMT for the lightest non load bearing studs up to 1.6mm BMT for heavy load bearing or high wind zone studs.
For a residential load bearing external wall at 450mm centres in a typical suburban wind zone (N2), the steel stud is usually 1.0mm or 1.15mm BMT in a 92mm C section. In higher wind zones or lower storey positions of a two storey building, 1.15 or 1.6mm BMT is used. The exact gauge is confirmed against the NASH Standard Part 2 span table for the specific loading and wind zone.
The stud spacing is set by the structural design, the stud and track profiles are cut to length from the manufactured sections, the bottom track is fixed to the floor along the wall line, studs are swaged or screwed into the bottom track, the top track is fitted and fixed to the studs, and the whole frame is braced square before being lined. For load bearing walls, the design has to follow the NASH Standard and the wall has to be erected in accordance with the engineering documentation, so this is work for a qualified builder working to specified drawings rather than a general how to.
Sometimes. 600mm centres is permitted for some residential external load bearing walls in lower wind zones with sheet cladding, and it is confirmed against the span table for the specific loading scenario. For brick veneer, higher wind zones, or lower storey walls in two storey buildings, 450mm centres is the standard choice.
Light gauge steel framing is the family of cold formed steel sections (studs, tracks, joists, trusses) used to frame residential, low rise commercial and light industrial buildings. The sections are rolled from thin gauge steel sheet (typically between 0.55mm and 1.6mm thick before coating) and designed under AS/NZS 4600, with system level design under the NASH Standard. It is the dominant steel framing approach in Australian low rise construction.
Light gauge steel studs are cut with a drop saw fitted with a metal cutting blade, with aviation snips for notches and openings, or with a nibbler for larger apertures. Angle grinders are used but leave a rough edge that compromises the coating at the cut; where possible the cut edges are de burred and treated. For accurate work, as much cutting as possible is done at the factory on CNC equipment rather than on site.
If you are planning a residential, commercial or industrial build and want practical numbers, drawings or product advice to work from, the CMC Steel Solutions team is a direct call away. Phone us on 1300 285 566, email info@cmcsteelsolutions.com.au, or request an obligation free quote and we will walk through your project, the standards that apply, and what the right steel framing solution looks like for your specific site.